Input | |
Measuring range limits | See “Dimensional drawings” |
Media pressure | 1 ... 100 bar (Higher pressures on request) |
Output | |
Current output | |
| 4 … 20 mA |
| 20.8 mA ± 1 % (105 % ± 1 %) |
| |
| 100 Ω |
| R max = (UPower Supply – 14 V)/22 mA |
| NAMUR NE 43 |
| 22 mA (112.5 %) |
| 4 mA |
Digital output | |
| HART |
| FSK |
| Transmitter |
Pulse Output (Passive pulse output, needs separate power supply. Pulse output has to be defined in the Option menu Y47 totalizer or energy unit has to be entered. E.g.: 1 pulse/kg or 1 pulse/10 m3) | |
| Max. 0.5 Hz |
| Min. 24 V DC as NAMUR or |
| open < 1 mA, max. 36 V, closed 100 mA, U < 2 V |
| open < 1 mA, max. 30 V, closed 100 mA, U < 2 V |
Accuracy | |
Standard version | |
| ± 0.75 % |
| |
| ± 1 % |
| |
- For steam, gases and liquids
| ± 2 % |
| |
Pressure and temperature compensated version | |
| |
| ± 2 % |
| ± 0.75 % |
| |
| ± 2.5 % |
| ± 1.5 % |
Repeatability | ± 0.1 % |
Installation conditions (At different conditions, e.g. installation after control valve, bends or reductions, please refer to the operating instructions.) | |
| ≥ 20 x DN |
| ≥ 5 x DN |
Software | |
Uncompensated for gases, steam and liquids, but temperature-compensated for saturated steam | Select 1 |
Density-compensated by temperature and pressure for superheated steam, no energy calculation | Select 4 |
Gross heat | |
When the device has to operate as a energy calculation device | Select 5 |
In options Y51 to Y56 add information regarding: | - Y51 Variable current output
- Y52 Power unit
Select one of the following units from power units table in Y52: kJ/h, MJ/h, GJ/h, Btu/h, kcal/h, kW, MW or special (custom) - Y53 Fullscale power value
- Y54 Variable pulse output
- Y55 Totalizer on/off
- Y56 Configures for totalizer
Select one of the following units from energy units table in Y56: kJ, MJ, GJ, Btu th, kcal, kWh, MWh or special (custom).
|
Gases and wet gases | Select 7 |
Wet gases | Select Y49 and enter relative humidity in % |
FAD - Free Air Delivery | |
When the device has to operate close to a compressor | Select 8 |
In Y81 to Y87 add information regarding: | - Y81 Inlet suction temperature
- Y82 Atmosphere pressure
- Y83 Pressure drop filter
- Y84 Inlet relative humidity
- Y85 Actual revolutions per minute (of compressor)
- Y86 Rated rpm of compressor
- Y87 Outlet relative humidity. This information is available from compressor supplier.
|
Mixed gases | When the fluid is a gas mixture, make an SDR request (sheet available on intranet) and fill in gas names and amount in % |
Rated operation conditions | |
Ambient temperature | |
| -40 … +85 °C (-40 … +185 °F) |
| -40 … +65 °C (-40 … +149 °F) |
Storage temperature | -50 … +85 °C (-58 … +185 °F) |
Media temperature | -40 … +240 °C (-40 … +464 °F) |
Density | Taken into consideration when rating |
Viscosity | < 10 cP |
Reynold's number | 10 000 … 2 300 000 |
Media pressure limit | Max. 100 bar (Higher pressure on request. Make an SDR request, sheet available on intranet) |
Design | |
Material | |
| 1.4404 (316L)/1.4435 (316L) Hastelloy C22 available (make an SDR request, sheet available on intranet) |
| Aluminium Aluminium (paint petrol) for increased requirement |
- Sensor gaskets: for pick-up and pressure sensor
| 1.4435 (316L)/FPM or FFKM FPM (Viton®) by steam and non-aggressive gases. FFKM (Kalrez®) by chlorine and other aggressive gases (only available together with a pressure sensor). |
Process connections | Flange norm EN 1092-1 form B1/B2 or ASME B16.5 RF. Other flanges on request. Make an SDR request, sheet available on intranet |
| DN 15 … 300 (½ … 12") |
| DN 15 … 100 (½ … 4") |
Degree of protection | IP66/IP67 |
Dimensions and weights | See “Dimensional drawings” |
Display and operating interface | |
Local display | 2 lines, 10 characters per line |
Languages | German, English, French |
Power supply | |
| 14 … 36 V DC |
| 14 … 30 V DC |
Certificates and approvals | |
Explosion protection | |
| II 2G EEx d ia [ia] IIC T6 |
| Class I, II, III, Div 1 & 2 |
Calibration |
All flowmeters will be delivered with a 3 point calibration certificate |
Material Certificate |
Certificate of compliance, pressure test, material certificate, material in acc. of NACE and PMI of pressure bearing metal parts. |
Cleaning |
Choice Cleaning Class1 when fluid is oxygen or contains chloride. |
Certificates |
X-ray test on pressurized weldings and dye penetration test on pressure bearing weldings. |