Transmitter SITRANS F C MASS 6000 Ex d |
Measurement of | Mass flow [kg/s (lbs/min)], volume flow [l/s (gpm)], fraction [%], °Brix, density [kg/m33)], temperature [°C (°F)] (lbs/ft |
Current output | Classified EEx ia, selectable as active or passive outputs. Default setting is passive mode. |
| 0 ... 20 mA or 4 ... 20 mA |
| < 350 Ω |
| 0 ... 99.9 s adjustable |
Current characteristics | |
Active mode | Uo = 24 V, Io = 82 mA, Po = 0.5 W, Co = 125 nF, Lo = 2.5 mH |
Passive mode (max input from external barrier) | Ui = 30 V, Ii = 100 mA, Pi = 0.75 W, Ci = 52 nF, Li = 100 μH |
Digital output | |
| 0 ... 10 kHz, 50 % duty cycle |
| 0.1 ... 30 s adjustable |
| 6 ... 30 V DC, max. 110 mA, 1 KΩ ≤ Rload ≤ 10 KΩ |
Output characteristics | |
Active mode | Not available |
Passive mode (max input from external barrier) | Ui = 30 V, Ii = 100 mA, Pi = 0.75 W, Ci = 52 nF, Li = 100 μH |
Relay | |
| Change-over relay |
| 30 V/100 mA |
| Error level, error number, limit, direction |
| Ui = 30 V, Ii = 100 mA, Pi = 0.75 W, Ci = 0 nF, Li = 0 mH |
Digital input | 11 ... 30 V DC (Ri = 13.6 KΩ) |
| Start/hold/continue batch, zero point adjust, reset totalizer 1/2, force output, freeze output |
| Ui = 30 V, Ii = 3.45 mA, Pi = 0.10 W, Ci = 0 nF, Li = 0 mH |
Galvanic isolation | All inputs and outputs are galvanically isolated, isolation voltage 500 V |
Cut-off | |
| 0 ... 9.9 % of maximum flow |
| Detection of empty sensor |
| 0 ... 2.9 g/cm3 |
Totalizer | Two eight-digit counters for forward, net or reverse flow |
Display | - Background illumination with alphanumerical text, 3 × 20 characters to indicate flow rate, totalized values, settings and faults. Time constant as current output
- Reverse flow indicated by negative sign
|
Zero point adjustment | Manual via keypad or remote via digital input |
Ambient temperature | |
| -20 ... +50°C (-4 ... +122 °F) |
| -40 ... +70°C (-4 ... +158 °F) (Humidity max. 95 %) |
Communication | Add-on modules: HART, PROFIBUS PA, FOUNDATION Fieldbus H1 |
HART | |
Active mode | Uo = 6.88 V, Io = 330 mA, Po = 0.57 W, Co = 20 nF, Lo = 100 μH |
Passive mode (max input from external barrier) | Ui = 10 V, Ii = 200 mA, Pi = 0.5 W, Ci = 0 nF, Li = 0 μH |
PROFIBUS PA | |
Active mode | Not available |
Passive mode | Ui = 17.5 V, Ii = 380 mA, Pi = 5.32 W, Ci = 5 nF, Li = 10 μH |
FOUNDATION Fieldbus H1 | |
Active mode | Not available |
Passive mode | Ui = 17.5 V, Ii = 380 mA |
Enclosure | |
| Stainless steel AISI 316 W1.4435 |
| - Compact mounted on sensor: IP67/NEMA 4X to IEC 529 and DIN 40050
- Remote mounted: IP66/NEMA 4 to IEC 529 and DIN 40050
|
| 18 ... 1000 Hz random, 1.14 G rms, in all directions, to IEC 68-2-36, Curve E |
Supply voltage | |
24 V AC | |
| 20 ... 30 V AC |
| 6 VA IN = 250 mA, IST = 2 A (30 ms) |
| The power supply shall be from a safety isolating transformer. Maximal cable core is 1.5 mm2 |
24 V DC | |
| 18 ... 30 V DC |
| 6 VA IN = 250 mA, IST = 2 A (30 ms) |
| The power supply shall be from a safety isolating transformer. Maximal cable core is 1.5 mm2 |
EMC performance | |
| EN 50081-1 (Light industry) |
| EN 50082-2 (Industry) |
NAMUR | Within the value limits according to "Allgemeine Anforderung" with error criteria A in accordance with NE 21 |
Ex approval | EEx-de [ia/ib] IIC T6, DEMKO 03 ATEX 13253X |
Temperature class: | Process liquid temperature: |
| |
| - 85 °C < T < 100 °C (185 °F < T < 212 °F)
|
| - 100 °C < T < 135 °C (212 °F < T < 275 °F)
|
| - 135 °C < T < 180 °C (275 °F < T < 356 °F)
|