MASS 6000 IP67 compact/remote


Mã sản phẩm: 7ME4110
Tên sản phẩm: MASS 6000 IP67 compact/remote




Transmitter SITRANS F C MASSFLO MASS 6000 Compact IP67/NEMA 4X

Measurement of

Mass flow [kg/s (lbs/min)], volume flow [l/s (gpm)], fraction [%], °Brix, density [kg/m3, (lbs/ft3)], temperature [°C (°F)]

Current output

 
  • Current

0 ... 20 mA or 4 ... 20 mA

  • Load

< 800 Ω

  • Time constant

0 ... 99.9 s adjustable

Digital output

 
  • Frequency

0 ... 10 kHz, 50% duty cycle

  • Time constant

0 ... 99.9 s adjustable

  • Active

24 V DC, 30 mA, 1 KΩ ≤ Rload ≤ 10 KΩ, short-circuit-protected

  • Passive

3 ... 30 V DC, max. 110 mA, 1 KΩ ≤ Rload ≤ 10 KΩ

Relay

 
  • Type

Change-over relay

  • Load

42 V/2 A peak

  • Functions

Error level, error number, limit, flow direction

Digital input

11 ... 30 V DC (Ri = 13.6 KΩ)

  • Functionality

Start/hold/continue batch, zero point adjust, reset totalizer 1/2, force output, freeze output

Galvanic isolation

All inputs and outputs are galvanically isolated, isolation voltage 500 V

Cut-off

 
  • Low-flow

0 ... 9.9 % of maximum flow

Limit function

Mass flow, volume flow, fraction, density, sensor temperature

Totalizer

Two eight-digit counters for forward, net or reverse flow

Display

  • Background illumination with alphanumerical text, 3 × 20 characters to indicate flow rate, totalized values, settings and faults. Time constant as current output 1
  • Reverse flow indicated by negative sign

Zero point adjustment

Manual via keypad or remote via digital input

Ambient temperature

 
  • Operation

-20 ... +50 °C (-4 ... +122 °F), max. rel. humidity 80% to 31 °C (87.8 °F) decreasing to 50% at 40 °C (104 °F) according to IEC/EN/UL 61010-1

  • Storage

-40 ... +70 °C (-4 ... +158 °F) (Humidity max. 95 %)

Communication

Add-on modules: HART, PROFIBUS PA & DP, MODBUS RTU RS 485, DeviceNet, FOUNDATION Fieldbus H1

Enclosure

 
  • Material

Fibre glass-reinforced polyamide

  • Rating

IP67/NEMA 4X to IEC 529 and DIN 40050 (1 m w.g. for 30 min.)

  • Mechanical load

18 ... 1000 Hz random, 3.17G rms, in all directions, to IEC 68-2-36

Supply voltage

 

24 V version

 
  • Supply

24 V DC/AC, 50 ... 60 Hz

  • Fluctuation

18 ... 30 V DC
20 ... 30 V AC

  • Power consumption

10 W

230 V version

 
  • Supply

87 ... 253 V AC, 50 ... 60 Hz

  • Power consumption

26 VA

Fuse

 
  • 230 V version

T400 mA, T 250 V (IEC 127) - Not to be changed by user

  • 24 V version

T1 A, T 250 V (IEC 127) - Not to be changed by user

EMC performance

 
  • Emission

EN/IEC 61000-6-4 (Industry)

  • Immunity

EN/IEC 61000-6-2 (Industry)

NAMUR

Within the value limits according to "Allgemeine Anforderung" with error criteria A in accordance with NE 21

Environment

 
  • Environmental conditions acc. to IEC/EN/UL 61010-1:
  • Altitude up to 2000 m
  • POLLUTION DEGREE 2

Maintenance

The flowmeter has a built-in error log/pending menu which should be inspected on a regular basis

Cable glands

Two types of cable gland are available in polyamide in the following dimensions: M20 or ½” NPT



http://anphatautomation.com/MASS 6000 for 19" insert/19" wall mounting
MASS 6000 for 19" insert/19" wall mounting


Mã sản phẩm: 7ME4110
Tên sản phẩm: MASS 6000 for 19" insert/19" wall mounting




SITRANS F C MASSFLO MASS 6000 19” IP20/NEMA 1 or IP66/NEMA 4 version

Measurement of

Mass flow [kg/s (lbs/min)], volume flow [l/s (gpm)], fraction [%], °Brix, density [kg/m33)], temperature [°C (°F)] (lbs/ft

Current output

 
  • Current

0 ... 20 mA or 4 ... 20 mA

  • Load

< 800 Ω

  • Time constant

0 ... 99.9 s adjustable

Digital output

 
  • Frequency

0 ... 10 kHz, 50 % duty cycle

  • Time constant

0 ... 30 s adjustable

  • Active

24 V DC, 30 mA, 1 KΩ ≤ Rload ≤ 10 KΩ, short-circuit-protected

  • Passive

3 ... 30 V DC, max. 110 mA, 1 KΩ ≤ Rload ≤ 10 KΩ

Relay

 
  • Type

Change-over relay

  • Load

42 V / 2 A peak

  • Functions

Error level, error number, limit, direction

Digital input

11 ... 30 V DC

  • Functionality

Start/hold/continue batch, zero point adjust, reset totalizer 1/2, force output, freeze output

Galvanic isolation

All inputs and outputs are galvanically isolated, isolation voltage 500 V

Cut-off

 
  • Low-flow

0 ... 9.9 % of maximum flow

Limit function

Mass flow, volume flow, fraction, density, sensor temperature

Totalizer

Two eight-digit counters for forward, net or reverse flow

Display

  • Background illumination with alphanumerical text, 3 × 20 characters to indicate flow rate, totalized values, settings and faults
  • Reverse flow indicated by negative sign

Zero point adjustment

Manual via keypad or remote via digital input

Ambient temperature

 
  • Operation

-20 ... +50°C (-4 ... +122 °F)

  • Storage

-40 ... +70°C (-40 ... +158 °F) (Humidity max. 95 %)

Communication

Add-on modules: HART, PROFIBUS PA and DP, MODBUS RTU RS 485, DeviceNet, FOUNDATION Fieldbus H1

Enclosure 19”

 
  • Material

Aluminium/steel (DIN 41494)

  • Rating

IP20/NEMA 1 to IEC 529 and DIN 40050 (1 m w.g. for 30 min.)

  • Mechanical load

18 ... 1000 Hz random, 3.17G rms, in all directions, to IEC 68-2-36

Supply voltage

  • 87 ... 253 V AC +10% ... -10%, 50 ... 60 Hz
  • 18 ... 30 V DC or 20 ... 30 V AC

Power consumption

 
  • 230 V AC

9 VA max.

  • 24 V DC

6 W IN = 250 mA, IST = 2 A (30 ms)

EMC performance

 
  • Emission

EN/IEC 61000-6-4 (Industy)

  • Immunity

EN/IEC 61000-6-2 (Industy)

Ex approval

[EEx ia] IIC, DEMKO 03 ATEX 135251X

Maintenance

The flowmeter has a built-in error log/pending menu which should be inspected on a regular basis

Fuse

T 400 mA, T 250 V (IEC 127), not replaceable by operator

Cable

  • Max. 300 m
  • C: max. 300 [pF/m]; LC/RC: max. 100 [μH/Ω]
  • The total cable capacity must be max. 200 nF

Cable glands

The cable gland is available in polyamide, in dimension: PG 13.5

 


Overview:

 