Measuring principle | Electromagnetic induction | Electromagnetic induction |
Excitation frequency | - DN 2 ... 65 (1/12“ … 2½”): 12.5 Hz
- DN 80, 100 (3”, 4”): 6.25 Hz
| - DN 15 ... 50 (½“ … 2”): 12.5 Hz
- DN 80, 100 (3”, 4”): 6.25 Hz
|
Process connection | | |
Nominal size | | |
| DN 2 … DN 100 (1/12" … 4") | DN 15 … DN 100 (½” … 4") |
| DN 10 … DN 100 (3/8" … 4") | |
Mating flanges | EN 1092-1 (DIN 2501), ANSI B 16.5 class 150 and 300 or equivalent Option: DN 2 ... 10 (1/12” ... 3/8”): G½” / NPT ½” pipe connection adapters | EN 1092-1 (DIN 2501), ANSI B 16.5 class 150 and 300 or equivalent |
Rated operating conditions | | |
Ambient conditions | | |
Ambient temperature1) | | |
| -40 … +100 °C (-40 … +212 °F) | -40 … +100 °C (-40 … +212°F) |
| -20 … +60 °C (-4 … +140 °F) | |
- Compact transmitter MAG 5000/6000
| -20 … +50 °C (-4 … +122°F) | |
- Compact transmitter MAG 6000 I
| -20 … +60 °C (-4 … +140 °F) | |
- Compact transmitter MAG 6000 I Ex d
| -10 … +60 °C (+14 … +140 °F) | |
Temperature of medium | | |
| -20 … +150 °C (-4 … +302°F) | -20 … +200 °C (-4 … +392°F) |
| -20 … +150 °C (-4 … +302°F) | -20 … +180C (-4 … +356°F) |
| -30 … +130 °C (-20 … +266F) Suitable for steam sterilization at 150 °C (302°F) | |
Temperature shock | | |
| | |
- Duration ≤ 1 min, followed by 10 min rest
| - DN 2, 3 (1/12”, 1/8”) No limitations
- DN 6, 10, 15, 25:
Max. DT ≤ 80 °C/min (¼”, 3/8”, ½”, 1”: Max. DT ≤ 80 K/min) - DN 40, 50, 65:
Max. DT ≤ 70 °C/min (1½”, 2”, 2½”: Max. DT ≤ 70 K/min) - DN 80, 100: Max. DT ≤ 60 °C/min (3”, 4”: Max. DT ≤ 60 K/min)
| - DN 15, 25: Max. DT ≤ 80 °C/min (½”, 1”: Max. DT ≤ 80 K/min)
- DN 40, 50: Max. DT ≤ 70 °C/min (1½”, 2”: Max. DT ≤ 70 K/min)
- DN 80, 100: Max. DT ≤ 60 °C/min (3”, 4”: Max. DT ≤ 60 K/min)
|
| Max. ±100 °C (210 °F) momentarily | |
Operating pressure | | |
| - DN 2 ... 65: 40 bar
(1/12” … 2½”: 580 psi) - DN 80: 37.5 bar (3”: 540 psi)
- DN 100: 30 bar (4”: 435 psi)
Vacuum: 1 x 10-6abs1.5 x 10-5 psiabs bar | - DN 15 ... 50: 40 bar
(½” … 2”: 580 psi) - DN 80: 37.5 bar (3”: 540 psi)
- DN 100: 30 bar (4”: 435 psi)
Vacuum: 1 x 10-6abs1.5 x 10-5 psiabs) bar |
| 20 bar (290 psi) Vacuum: 0.02 barabs (0.3 psiabs) DN 80 ... DN 100: CO2pressure max. 7 bar (101.5 psi) | |
Mechanical load | - 18 … 1 000 Hz random in x, y z, directions for 2 hours according to EN 60068-2-36
- Sensor: 3.17 grms
- Sensor with compact MAG 5000/ 6000 mounted transmitter: 3.17 grms
- Sensor with compact MAG 6000 I/ 6000 I Ex mounted transmitter: 1.14 grms
- For compact installation with the MAG 6000 I, transmitter to be supported to avoid tension on sensor part.
| - 18 … 1 000 Hz random in x, y z, directions for 2 hours according to EN 60068-2-36
- Sensor: 3.17 grms
|
Enclosure rating | | |
| IP67 to EN 60529 (NEMA 4X/6), 1 mH2O for 30 min | IP67 to EN 60529 (NEMA 4X/6), 1 mH2O for 30 min |
- Option on sensor (no ATEX)
| IP68 to EN 60529 (NEMA 6P), 10 mH2O cont. | IP68 to EN 60529 (NEMA 6P), 10 mH2O cont. |
EMC | 89/336 EEC | 89/336 EEC |
Design | | |
Weight | See Dimensional drawings | See Dimensional drawings |
Material | | |
| | |
| Stainless steel AISI 316L (1.4404) | Stainless steel AISI 316L (1.4404) |
| | |
| Fibre glass reinforced polyamide (no ATEX) | Stainless steel AISI 316 (1.4436) |
| Stainless steel AISI 316 (1.4436) | |
| Stainless steel AISI 304 (1.4301), Number and size to EN 1092-1:2001 | Stainless steel AISI 304 (1.4301), Number and size to EN 1092-1:2001 |
| | |
| EPDM (max. 150 °C, PN 40 (max. 300 °F, 600 psi) | Graphite (max. 200 °C, PN 40 (max. 390 °F, 600 psi) |
| - Graphite (max. 200 °C, PN 40 (max. 390 °F, 600 psi)
- PTFE (max. 130 °C, PN 25 (max. 270 °F, 300 psi)
| |
- Pipe connection adapters:
DN 2, 3, 6 and 10 (1/12“, 1/8“, ¼” and 3/8”)
| - Stainless steel, AISI 316
- Hastelloy
- PVDF
| |
Liner | | |
| - DN 2, 3 (1/12“, 1/8“): Zirconium oxide (ZrO2)
- DN 6 ... 100 (¼" ... 4"): Aluminium oxide Al2O3
| DN 15 ... 100 (½“, 4“): Aluminium oxide Al2O3 |
| Reinforced PFA (no ATEX) | |
Electrodes | | |
| - DN 10 ... 100 (3/8" ... 4") : Platinum with gold / Titanium brazing alloy
- DN 2 ... 6 (1/12" ... ¼"): Platinium
| Platinum with gold / Titanium brazing alloy |
| - DN 10 ... 15 (3/8" ... ½") : Hastelloy C276
- DN 25 ... 100 (1" ... 4") : Hastelloy C22
| |
Cable entries | - Remote installation 2 x M20 or 2 x ½” NPT
- Compact installation
- MAG 5000/MAG 6000: 4 x M20 or 4x½”NPT
- MAG 6000I: 2 x M25 (for supply/output)
- MAG 6000I Ex d: 2 x M20 (for supply/output)
| Remote installation 2 x M20 or 2 x ½“ NPT |
Certificates and approvals | | |
Conforms to | PED – 97/23 EC and CRN (PFA) | PED – 97/23 EC and CRN (PFA) |
Ex approvals | | |
MAG 1100 (Ceramic) | | |
- ATEX sensor or Compact with MAG 6000 I Ex
| ATEX 2G D sensor Ex d e ia IIB T3 - T6 | ATEX 2G D sensor Ex d e ia IIB T3 - T6 |
- Sensor with/without MAG 5000/6000 /6000 I
| CSA/FM Class 1 div 2 | CSA/FM Class 1 div 2 |
MAG 1100 (PFA) | | |
- Sensor with/without MAG 5000/6000/6000 I
| CSA/FM Class 1 div 2 | |