MAG 1100 F
|
|
Mã sản phẩm:
7ME6140
Tên sản phẩm:
MAG 1100 F
Measuring principle | Electromagnetic induction | Excitation frequency | DN 10 ... 65 (¼“ … 2½”): 12.5 Hz DN 80 ... 100 (3”, 4”): 6.25 Hz | Process connection | | Nominal size | DN 10 … DN 100 (3/8" … 4") | Process connection | Hygienic adapters available for: - Direct welding onto pipe
- Clamp fitting
- Threaded fitting
| Rated operating conditions | | Ambient conditions | | Ambient temperature1) | | | -40 … +100°C (-40 … +212 °F) | | -20 … +60°C (-4 … +140 °F) | - Compact transmitter MAG 5000/6000
| -20 … +50°C (-4 … +122 °F) | | -20 … +60°C (-4 … +140 °F) | - Compact transmitter MAG 6000 I Ex d
| -10 … +60°C (+14 … +140 °F) | Temperature of medium | | MAG 1100 F (Ceramic) | -20 … +150 °C (-4 … +300 °F) Suitable for steam sterilization | MAG 1100 F (PFA) | -30 … +130 °C (-20 … +270 °F) Suitable for steam steralization at 150 °C (300 °F) | Temperature shock | | MAG 1100 F | | - Duration ≤ 1 min, followed by 10 min rest
| - DN 10, 15, 25: Max. ΔT ≤ 80 °C/min
(3/8”, ½”, 1”: Max. ΔT ≤ 80 K/min) - DN 40, 50, 65: Max. ΔT ≤ 70 °C/min
(1½”, 2”, 2½”: Max. ΔT ≤ 70 K/min) - DN 80, 100: Max. ΔT ≤ 60 °C/min
(3”, 4”: Max. ΔT ≤ 60 K/min)
| MAG 1100 F (PFA) | Max. ±100 °C (210 °F) momentarily | Operating pressure | | MAG 1100 F (Ceramic) | - DN 10 ... 65: 40 bar (3/8” … 2½”: 580 psi)
- DN 80: 37.5 bar (3”: 540 psi)
- DN 100: 30 bar (4”: 435 psi)
Vacuum: 1 x 10-6 barabs-5 psiabs) (1.5 x 10 | MAG 1100 F (PFA) | 20 bar (290 psi) Vacuum: 0.02 barabs (0.3 psiabs) | Mechanical load | 18 ... 1 000 Hz random in x, y z, directions for 2 hours according to EN 60068-2-36 Sensor: 3.17 grms Sensor with compact MAG 5000/ 6000 mounted transmitter: 3.17 grms Sensor with compact MAG 6000 I/MAG 6000 I Ex mounted transmitter: 1.14 grms For compact installation with the MAG 6000 I/MAG 6000 I Ex, transmitter to be supported to avoid tension on sensor part. | Enclosure rating | | | IP67 to EN 60529 (NEMA 4X), 1 mH2O for 30 min | | IP68 to EN 60529 (NEMA 6), 10 mH2O cont. | EMC | 89/336 EEC | Design | | Weight | See Dimensional drawings | Material | | Enclosure | | | Stainless steel AISI 316L (1.4404) | Terminal box (remote version only) | | | Fibre glass-reinforced polyamide | | Stainless steel AISI 316 (1.4436) | - Ex ATEX (remote version only)
| Stainless steel AISI 316 (1.4436) | Liner | | MAG 1100 F (Ceramic) | Aluminium oxide Al2O3 (ceramics) | MAG 1100 F (PFA) | Reinforced PFA (teflon) (no ATEX) | Electrodes | | MAG 1100 F (Ceramic) | Platinum with gold / Titanium brazing alloy | MAG 1100 F (PFA) | - DN 10 ... 15 (3/8” … ½”): Hastelloy C276
- DN 25 … 100 (1” … 4”): Hastelloy C22
| Cable entries | - Remote installation 2 x M20 or 2x½ NPT
- Compact installation
- MAG 5000/MAG 6000: 4 x M20 or 4 x ½”NPT
- MAG 6000I: 2 x M25(for supply/output)
- MAG 6000I Ex. d: 2 x M20 (for supply/output)
| Certificates and approvals | | MAG 1100 F (Ceramic) | 3A (sensor with Polyamid terminal box ), transmitter not part of the approval | - Ex ATEX approvals for sensor or compact with Mag 6000 I Ex
| ATEX 2G D sensor EEx d e ia IIB T3 - T6 | - Sensor with/without MAG 5000/6000/ 6000 I
| CSA/FM Class 1 div 2 | MAG 1100 F (PFA) | 3A (sensor with Polyamid terminal box ) , transmitter not part of the approval CSA/FM Class 1 div 2 | Conforms to | PED – 97/23/EC and CRN (PFA) FDA |
1) Conditions are also dependent on liner characteristics AccessoriesWeld-in adapter | | Adapter for welding onto dairy pipe | Tri-Clover ISO 2037, DIN 11850, SMS 3008, BS 4825‑1 | - DN 10, 15, 25, 40, 50, 65 and 80 (3/8”, ½”, 1”, 1½”, 2”, 2½” and 3”)
| PN 40 (600 psi) | | PN 25 (350 psi) | Clamp adapter | Tri-Clamp, ISO 2852, DIN 32676, SMS 3016, BS 4825‑3 | DN 10, 15, 25, 40 and 50 (3/8”, ½”, 1”, 1½”, and 2”) | PN 16 (200 psi) | DN 65, 80 and 100 (2½”, 3” and 4”) | PN 10 (150 psi) | Thread adapter | | DIN 1181 | | - DN 10, 15, 25, and 40 (3/8”, ½”, 1”, and 1½”)
| PN 40 (600 psi) | - DN 50, 65, 80 and 100 (2”, 2½”, 3” and 4”)
| PN 25 (350 psi) | ISO 2853, BS 4825-4 | | - DN 10, 15, 25, 40, 50, 65 and 80 (3/8”, ½”, 1”, 1½”, 2”, 2½ and 3”)
| PN 16 (200 psi) | SMS 1145 | | - DN 25, 40, 50, 65 and 80 (1”, 1½”, 2”, 2½” and 3”)
| PN 6 (80 psi) | Design | | Material | | Adapter | Stainless steel AISI 316/Stainless steel AISI 304 (ISO 2852) | Gasket | | | FKM/FPM with stainless steel insert (AISI 304) (-20 ... +150 °C (-4 ... +302 °F)) | | EPDM (-20 ... +150 °C (-4 ... +302 °F)) NBR (-20 ... +100 °C (-4 ... +212 °F)) |
Note: When combined sensor and adapter, the operating pressure is the lower rated of the pair.
|