MAG 5100 W


Mã sản phẩm: 7ME6520
Tên sản phẩm: MAG 5100 W



 

Design

Full bore sensor

Coned bore sensor

Full bore sensor

Nominal size

DN 25 ... 40 (1” ... 1½”)

DN 50 ... 300 (2” ... 12”)

DN 350 ... 1200 (14” ... 48”)

Measuring principle

Electromagnetic induction

Excitation frequency

12.5 Hz

  • DN 50 ... 65 (2” ... 2½“): 12.5 Hz
  • DN  80 ... 150 (3” ... 6“): 6.25 Hz
  • DN  200 ... 300 (8” ... 12“): 3.125 Hz

1.56 Hz

Process connection

Flanges

 

Flat face flanges

 
  • EN 1092-1

PN 40 (580 psi)

  • DN  50 ... 300: PN 16
    (2“ ... 12“: 230 psi)
  • DN  200 ... 300: PN 10
    (8“ ... 12“: 145 psi)
  • PN 10 (145 psi)
  • PN 16 (230 psi)
  • ANSI B16.5

Class 150 lb

Class 150 lb ~20 bar (290 psi)

--

  • AWWA C-207

--

--

28” ... 48”: Class D

  • AS 4087

PN 16 (230 psi) DN 50 ... 1200 (2” ... 48”), 14 bar (232 psi)

Rated Operation conditions

Ambient temperature

   
  • Sensor

-40 ... +100 °C (-40 ... +212 °F)

  • With compact transmitter MAG 5000/6000

-20 ... +50 °C (-4 ... +122 °F)

  • With compact transmitter MAG 6000 I

-20 ... +60 °C (-4 ... +140 °F)

Operating pressure (Abs)

0.01 ... 40 bar (0.15 ... 580 psi)

0.03 ... 20 bar (0.44 ... 290 psi)

0.01 ... 16 bar (0.15 ... 232 psi)

Enclosure rating

   
  • Standard

IP67 to EN 60529 / NEMA 4X/6 (1 mH2O for 30 minutes)

  • Option

IP68 to EN 60529 / NEMA 6P (10 mH2O continuously)

Pressure drop at 3 m/s (10 ft/s)

As straight pipe

Max. 25 mbar (0.36 psi)

As straight pipe

Medium conditions

   

Temperature of medium

 
  • NBR

-10 ... +70 °C (14 ... +158 °F)

  • EPDM

-10 ... +70 °C (14 ... +158 °F)

EMC

89/336 EEC

Design

   

Weight

See dimensional drawings

Material

   
  • Housing and flanges

Carbon steel, St 37.2

  • Terminal box

Standard Fibre glass reinforced polyamide

  • Measuring pipe

AISI 304 (1.4301)

  • Liner

NBR Hard Rubber ((hydro carbon resistent)
EPDM

  • Electrodes

Hastelloy C276

  • Grounding electrodes standard

Hastelloy C276

Certificates and approvals

Custody Transfer (only together with MAG 5000/6000 CT), order as special

OIML R 49 pattern approval cold water (Denmark and Germany): DN 50 ... 300 (2" ... 12")

MI 001 cold water (EU): DN 50 ... 300 (2" ... 12")

Approvals

CSA/FM Class 1, Div 2

Drinking water approvals

 
  • EPDM

NSF61 (Cold water, US)
WRAS (WRc, BS6920 cold water, GB)
ACS listed (F), 
DVGW W270 (D) 
Belaque (B)

  • NBR

NSF61 (Cold water, US)

Approvals

PED – 97/23 EC1) , CRN


1) For sizes larger than 600 mm (24”) in PN 16 PED conformity is available as a cost added option. The basic unit will only carry the LVD (Low Voltage Directive) and EMC approval.