| HART | PROFIBUS PA or Foundation fieldbus |
Input | |
Measured variable | Absolute pressure |
Spans (infinitely adjustable) or nominal measuring range and max. permissible operating pressure | Span | Maximum operating pressure | Nominal measuring range | Maximum operating pressure |
| 8.3 ... 250 mbar a (0.12 ... 3.6 psi a) | 32 bar a (464 psi a) | 250 mbar a (3.6 psi a) | 32 bar a (464 psi a) |
| 43 ... 1300 mbar a (0.62 ... 18.9 psi a) | 32 bar a (464 psi a) | 1300 bar a (18.9 psi a) | 32 bar a (464 psi a) |
| 160 ... 5000 mbar a (2.32 ... 72.5 psi a) | 32 bar a (464 psi a) | 5 bar a (72.5 psi a) | 32 bar a (464 psi a) |
| 1 ... 30 bar a (14.5 ... 435 psi a) | 160 bar a (2320 psi a) | 30 bar a (435 psi a) | 160 bar a (2320 psi a) |
| 5.3 ... 100 bar a (76.9 ... 1450 psi a) | 160 bar a (2320 psi a) (for connection thread M10 and7/16-20 UNF in the process flanges) | 100 bar a (1450 psi a) | 160 bar a (2320 psi a) (for connection thread M10 and7/16-20 UNF in the process flanges) |
Lower measuring limit | | |
- Measuring cell with silicone oil filling
| 0 mbar a (0 psi a) |
Upper measuring limit | 100% of max. span |
Output | | |
Output signal | 4 ... 20 mA | Digital PROFIBUS PA or Foundation fieldbus signal |
- Lower limit (infinitely adjustable)
| 3.55 mA, factory preset to 3.84 mA | - |
- Upper limit (infinitely adjustable)
| 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA | - |
Load | |
- Without HART communication
| R B ≤ (UH - 10.5 V)/0.023 A in Ω, UH : Power supply in V | - |
| R B = 230 ... 500 Ω (SIMATIC PDM) or RB = 230 ... 1100 Ω (HART Communicator) | - |
Physical bus | - | IEC 61158-2 |
With polarity reversal protection | - | Yes |
Measuring accuracy | Acc. to EN 60770-1 |
Reference conditions (All error data refer always refer to the set span) | Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 25 °C (77 °F)) r: Span ratio (r = max. span / set span) |
Error in measurement and fixed-point setting (including hysteresis and repeatability) | |
| | ≤ 0.1 % |
| ≤ 0.1 % | |
| ≤ 0.2 % | |
Long-term drift (temperature change ±30 °C (±54 °F)) | ≤ (0.1 · r)%/year | ≤ 0.1 %/year |
Influence of ambient temperature | |
- at -10 ... +60 °C (14 ... 140 °F)
| ≤ (0.1 · r + 0.2)% | ≤ 0.3 % |
- at -40 ... -10 °C and +60 ... +85 °C
(-40 ... +14 °F and 140 ... 185 °F)
| ≤ (0.1·r + 0.15) %/10 K | ≤ 0.25 %/10 K |
Measured Value Resolution | - | 3 · 10-5 of nominal measuring range |
Conditions of use | |
Degree of protection (to EN 60529) | IP65 |
Temperature of medium | |
- Measuring cell with silicone oil filling
| -40 ... +100 °C (-40 ... +212 °F) |
- Measuring cell with inert filling liquid
| -20 ... +100 °C (-4 ... +212 °F) |
- In conjunction with dust explosion protection
| -20 ... +60 °C (-4 ... +140 °F) |
Ambient conditions | |
| |
| -30 ... +85 °C (-22 ... +185 °F) |
| -50 ... +85 °C (-58 ... +185 °F) |
| |
| Permissible |
- Electromagnetic Compatibility
| |
| Acc. to EN 50081-1 |
| Acc. to EN 61326 and NAMUR NE 21 |
Design | |
Weight (without options) | ≈ 4.5 kg (≈ 9.9 lb) |
Enclosure material | Low-copper die-cast aluminum, GD-AlSi 12 or stainless steel precision casting, Mat. No. 1.4408 |
Wetted parts materials | |
| Stainless steel, mat. No. 1.4404/316L or Hastelloy C276, mat. No. 2.4819, Monel, mat. No. 2.4360, tantalum or gold |
- Process flanges and sealing screw
| Stainless steel, mat. No. 1.4408, Hastelloy C4, mat. No. 2.4610 or Monel, mat. No. 2.4360 |
| FPM (Viton) or optionally: PTFE, FEP, FEPM and NBR |
Measuring cell filling | Silicone oil or inert filling liquid (max. 160 bar (2320 psi a) with oxygen measurement) |
Process connection | ¼-18 NPT and flange connection with mounting thread M10 to DIN 19213 or 7/16-20 UNF to EN 61518 |
Material of mounting bracket | |
| Sheet-steel, Mat. No. 1.0330, chrome-plated |
| Sheet stainless steel, mat. No. 1.4301 (SS 304) |
Power supply U H | | Supplied through bus |
Terminal voltage on transmitter | 10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode | - |
Separate 24 V power supply necessary | - | No |
Bus voltage | |
| - | 9 ...32 V |
- With intrinsically-safe operation
| - | 9 ...24 V |
Current consumption | |
| - | 12.5 mA |
- Startup current ≤ basic current
| - | Yes |
- Max. current in event of fault
| - | 15.5 mA |
Fault disconnection electronics (FDE) available | - | Yes |
Certificates and approvals | | |
Classification according to PED 97/23/EC | For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) |
Explosion protection | |
| PTB 99 ATEX 2122 |
| Ex II 1/2 G EEx ia/ib IIB/IIC T6 |
- Permissible ambient temperature
| -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +70 °C (-40 ... +158 °F) temperature class T5; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 |
| To certified intrinsically-safe circuits with maximum values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 Ω | FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA,Po = 1.2 W |
- Effective internal inductance/capacitance
| L i = 0.4 mH, Ci = 6 nF | L i = 7 μH, Ci = 1.1 nF |
| PTB 99 ATEX 1160 |
| Ex II 1/2 G EEx d IIC T4/T6 |
- Permissible ambient temperature
| -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 |
| To circuits with values:UH = 10.5 ... 45 V DC | To circuits with values:UH = 9 ... 32 V DC |
- Dust explosion protection for zone 20
| PTB 01 ATEX 2055 |
| Ex II 1 D IP65 T 120 °C Ex II 1/2 D IP65 T 120 °C |
- Permissible ambient temperature
| -40 ... +85 °C (-40 ... +185 °F) |
| 120 °C (248 °F) |
| To certified intrinsically-safe circuits with maximum values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 Ω | FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA,Po = 1.2 W |
- Effective internal inductance/capacitance
| L i = 0.4 mH, Ci = 6 nF | L i = 7 μH, Ci = 1.1 nF |
- Dust explosion protection for zone 21/22
| PTB 01 ATEX 2055 |
| Ex II 2 D IP65 T 120 °C |
| To circuits with values:UH = 10.5 ... 45 V DC;Pmax = 1.2 W | To circuits with values:UH = 9 ... 32 V DC; Pmax= 1.2 W |
- Type of protection "n" (zone 2)
| TÜV 01 ATEX 1696 X | Planned |
| Ex II 3 G EEx nA L IIC T4/T5/T6 | - |
- Explosion protection acc. to FM
| Certificate of Compliance 3008490 |
- Identification (XP/DIP) or (IS); (NI)
| CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III |
- Explosion protection to CSA
| Certificate of Compliance 1153651 |
- Identification (XP/DIP) or (IS)
| CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III |