http://anphatautomation.com/SITRANS F M MAG 8000 / MAG 8000 CT
SITRANS F M MAG 8000 / MAG 8000 CT


Mã sản phẩm: 7ME6810/7ME6820
Tên sản phẩm: SITRANS F M MAG 8000 / MAG 8000 CT




Description
The battery-operated SITRANS F M MAG 8000 / SITRANS F M MAG 8000 CT solution gives you the flexibility to install a reliable water flow meter virtually anywhere without sacrificing accuracy or performance. No mains power is required. The battery water flow meter complies with the custody transfer approvals MID and OIML R49 water meter standards and is specially engineered for stand-alone water applications such as abstraction, distribution network, revenue metering and irrigation.
Application Examples: Abstraction and distribution network, Revenue and bulk metering and Irrigration

Benefits

  • Simple placement of the meter - burry the meter underground and Floating chamber IP 68 (NEMA 6P) design is unaffected by meter position or in-line piping stresses and there is no requirement for filters
  • Low pressure loss - an unrestricted flow tube ensures minimal pressure loss, even at the highest flow rates. Overall network system pressures can be reduced, helping to prevent leakage from burst pipes and excess stress placed on pumping stations
  • Zero maintenance - designed without moving parts and has a 10-year battery life 
  • Measurement in both directions- one meter required for measuring in both direction
  • Intelligent meter- one meter for (leak detection, data logger function, self detection of errors)

Detail

 

 Nominal size

From DN 25 to DN 1200 (1" to 48")
From DN 50 to DN 300 (1" to 12") (SITRANS F M MAG 8000 CT)

 Accuracy0.2% ± 2mm/s and 0.4% ± 2mm/s
 Input / output2 passive outputs
 Communication

IrDA: Standard integrated infrared communication interface with MODBUS RTU protocol

RS232 or RS485 serial interface with 
MODBUS RTU

Encoder interface (for Itron 200 WP) with "Sensus protocol"

 Power supplyInternal or external battery pack
12-24 V AC/DC and 115-230 V AC
 Operating pressureMax. 16 bar (Max. 150 psi)
 Ambient temperatureFrom -20 to 60 °C (-4 to 140 °F)
 Medium temperature

From 0 bis 70 °C (32 to 158 °F)
From 0.1 to 50 °C (32 to 122 °F) (SITRANS F M MAG 8000 CT)

 LinersEPDM
 Electrodes

Hastelloy C 276

 Enclosure

IP67 (NEMA 4)
IP68 (NEMA 6P)

 MaterialTransmitter:Stainless steel top housing (AISI 316) 
and coated brass bottom.
Sensor: Carbon steel
 ApprovalWRAS, KTW, DVGW 270, ACS, Belagua, NSF/ANSI Standard 61,
MID (EU), OIML R49, MCERTS Sira Certificate No. MC080137/00
 


http://anphatautomation.com/OCM III
OCM III


Mã sản phẩm: 7ML1002
Tên sản phẩm: OCM III



 

Measuring range1)

 0.3 to 1.2 m (1 to 4 ft) or 0.6 to 3 m (2 to 10 ft)

Output

 

Transducer

Echomax® XRS-5, 44 kHz

Relays

3 alarm/control relays, 1 SPDT Form C contact per relay, rated 5 A at 250 V AC non-inductive or 30 V DC

mA output

0/4 to 20 mA, isolated

  • Max. load

1 KΩ max. load

  • Resolution

5 uA

  • Isolation

300 V AC continuous

  • DC output

+24 V DC, 20 mA average to 200 mA at 1/10 duty cycle max. 0 to 20

Accuracy

 

Error in measurement

±1 mm/m, calculated error less than 0.02%

Resolution

0.2 mm (0.007")

Rated operating conditions

 

Installation conditions

 

Location

Indoor/outdoor

Installation category

II

Pollution degree

4

Ambient conditions

 

Ambient temperature (enclosure)

-20 to +50 °C (-5 to +122 °F)

Design

 

Weight

2.3 kg (5.1 lbs)

Material (enclosure)

Polycarbonate

Degree of protection (enclosure)

IP65/Type 4X/NEMA 4X

Cable

 

Transducer and mA output signal

  • Transducer: co-axial to be RG62-A/U low capacity
  • mA output signal to be 2 copper conductors, twisted, with foil shield/drain wire, 300 V 0.5 to 0.75 mm² (22 to 18 AWG)
  • Relay/power to be copper conductors per local requirements to meet 250 V 5 A contact rating

Max. separation between transducer and transceiver

183 m (600 ft)

Displays and controls

LCD 5 x 7 dot matrix display with 2 lines of 40 characters each

Programming

Via removable programmer and communication link

Memory

3 V battery (NEDA 5003LC or equivalent), operating life 1 year, SuperCap capacitor for back-up during battery replacement

Power supply

 

AC version

100/115/200/230 V AC ± 15%, 50/60 Hz, 20 VA max.

DC version

9 to 30 V DC, 8 W max.

Certificates and approvals

CE, FM, CSANRTL/C, MCERTS, 
C-TICK2)

Communication

RS-232 or ± 20 mA bipolar current loop, 300, 600, 1200, 2400, 4800, 9600, 19200 baud

Options

 

Temperature sensor

TS-2

Remote monitoring

Flow Reporter, a Windows®-based configuration software and data extractor

Velocity sensor

Consult with factory


1) Program range is defined as the empty distance to the face of the transducer plus any range extension
2) EMC performance available upon request
Windows® is a registered trademark of Microsoft Corporation



http://anphatautomation.com/MAG 5100 W
MAG 5100 W


Mã sản phẩm: 7ME6520
Tên sản phẩm: MAG 5100 W



 

Design

Full bore sensor

Coned bore sensor

Full bore sensor

Nominal size

DN 25 ... 40 (1” ... 1½”)

DN 50 ... 300 (2” ... 12”)

DN 350 ... 1200 (14” ... 48”)

Measuring principle

Electromagnetic induction

Excitation frequency

12.5 Hz

  • DN 50 ... 65 (2” ... 2½“): 12.5 Hz
  • DN  80 ... 150 (3” ... 6“): 6.25 Hz
  • DN  200 ... 300 (8” ... 12“): 3.125 Hz

1.56 Hz

Process connection

Flanges

 

Flat face flanges

 
  • EN 1092-1

PN 40 (580 psi)

  • DN  50 ... 300: PN 16
    (2“ ... 12“: 230 psi)
  • DN  200 ... 300: PN 10
    (8“ ... 12“: 145 psi)
  • PN 10 (145 psi)
  • PN 16 (230 psi)
  • ANSI B16.5

Class 150 lb

Class 150 lb ~20 bar (290 psi)

--

  • AWWA C-207

--

--

28” ... 48”: Class D

  • AS 4087

PN 16 (230 psi) DN 50 ... 1200 (2” ... 48”), 14 bar (232 psi)

Rated Operation conditions

Ambient temperature

   
  • Sensor

-40 ... +100 °C (-40 ... +212 °F)

  • With compact transmitter MAG 5000/6000

-20 ... +50 °C (-4 ... +122 °F)

  • With compact transmitter MAG 6000 I

-20 ... +60 °C (-4 ... +140 °F)

Operating pressure (Abs)

0.01 ... 40 bar (0.15 ... 580 psi)

0.03 ... 20 bar (0.44 ... 290 psi)

0.01 ... 16 bar (0.15 ... 232 psi)

Enclosure rating

   
  • Standard

IP67 to EN 60529 / NEMA 4X/6 (1 mH2O for 30 minutes)

  • Option

IP68 to EN 60529 / NEMA 6P (10 mH2O continuously)

Pressure drop at 3 m/s (10 ft/s)

As straight pipe

Max. 25 mbar (0.36 psi)

As straight pipe

Medium conditions

   

Temperature of medium

 
  • NBR

-10 ... +70 °C (14 ... +158 °F)

  • EPDM

-10 ... +70 °C (14 ... +158 °F)

EMC

89/336 EEC

Design

   

Weight

See dimensional drawings

Material

   
  • Housing and flanges

Carbon steel, St 37.2

  • Terminal box

Standard Fibre glass reinforced polyamide

  • Measuring pipe

AISI 304 (1.4301)

  • Liner

NBR Hard Rubber ((hydro carbon resistent)
EPDM

  • Electrodes

Hastelloy C276

  • Grounding electrodes standard

Hastelloy C276

Certificates and approvals

Custody Transfer (only together with MAG 5000/6000 CT), order as special

OIML R 49 pattern approval cold water (Denmark and Germany): DN 50 ... 300 (2" ... 12")

MI 001 cold water (EU): DN 50 ... 300 (2" ... 12")

Approvals

CSA/FM Class 1, Div 2

Drinking water approvals

 
  • EPDM

NSF61 (Cold water, US)
WRAS (WRc, BS6920 cold water, GB)
ACS listed (F), 
DVGW W270 (D) 
Belaque (B)

  • NBR

NSF61 (Cold water, US)

Approvals

PED – 97/23 EC1) , CRN


1) For sizes larger than 600 mm (24”) in PN 16 PED conformity is available as a cost added option. The basic unit will only carry the LVD (Low Voltage Directive) and EMC approval.



http://anphatautomation.com/MAG 5000/6000
MAG 5000/6000


Mã sản phẩm: 7ME6910/7ME6920
Tên sản phẩm: MAG 5000/6000




Mode of operation and design

 

Measuring principle

Electromagnetic with pulsed constant field

Empty pipe

Detection of empty pipe (special cable required in remote mounted installation)

Excitation frequency

Depend on sensor size

Electrode input impedance

> 1 x 1014 Ω

Input

 

Digital input

11 ... 30 V DC, Ri = 4. 4 KΩ

  • Activation time

50 ms

  • Current

IDC 11 V = 2.5 mA, IDC 30 V = 7 mA

Output

 

Current output

 
  • Signal range

0 ... 20 mA or 4 ... 20 mA

  • Load

< 800 Ω

Time constant

0.1 … 30 s, adjustable

Digital output

 
  • Frequency

0 ... 10 kHz, 50 % duty cycle (uni/bidirectional)

  • Pulse (active)

DC 24 V, 30 mA, 1 KΩ ≤ Ri ≤ 10 KΩ, short-circuit-protected (power supplied from flowmeter)

  • Pulse (passive)

DC 3 … 30 V, max. 110 mA, 200 Ω ≤ Ri ≤ 10 KΩ (powered from connected equipment)

  • Time constant

0.1 … 30 s, adjustable

Relay output

 
  • Time constant

Changeover relay, same as current output

  • Load

42 V AC/2 A, 24 V DC/1 A

Low flow cut off

0 ... 9.9 % of maximum flow

Galvanic isolation

All inputs and outputs are galvanically isolated

Max. measuring error (incl. sensor and zero point)

 
  • MAG 5000

0.5 % of rate

  • MAG 6000

0.25 % of rate

Rated operation conditions

 

Ambient temperature

 
  • Operation
  • Display version:

-20 ... +50  C (-4 ... +122  F)

  • Blind version:

-20 ... +60  C (-4 ... +140  F)

  • Storage

-40 ... +70  C (-40 ... +158 F°)

Mechanical load

 
  • Compact version

18 ... 1000 Hz, 3,17 G rms, sinusoidal in all directions to IEC 68-2-36

  • 19“ insert

1 ... 800 Hz, 1 G, sinusoidal in all directions to

IEC 68-2-36

Degree of protection

 
  • Compact version

IP67/NEMA 4X to IEC 529 and DIN 40050 (1 mH2O 30 min.)

  • 19“ insert

IP20/NEMA 2 to IEC 529 and DIN 40050

EMC performance

EN 61326-1 (all environments)

EN 61326-2-5

Display and keypad

 

Totalizer

Two eight-digit counters for forward, net or reverse flow

Display

Background illumination with alphanumeric text, 3 x 20 characters to indicate flow rate, totalized values, settings and faults; Reverse flow indicated by negative sign

  • Time constant

Time constant as current output time constant

Design

 

Enclosure material

 
  • Compact version

Fiber glass reinforced polyamide; optional (IP67 only):
AISI 316 stainless steel

  • 19“-insert

Standard 19“ insert of aluminium/steel (DIN 41494), width: 21 TE, height: 3 HE

  • Back of panel

IP20/NEMA 2; Aluminium

  • Panel mounting

IP65/NEMA 4; ABS plastic

  • Wall mounting

IP66/NEMA 4; ABS plastic

Dimensional drawings

 
  • Compact version

See dimensional drawings

  • 19“ insert

See dimensional drawings

Weight

 
  • Compact version

0.75 kg (2 lbs)

  • 19“ insert

See dimensional drawings

Power supply

  • 115 ... 230 V AC  +10 % -15 %, 50 ... 60 Hz, 17 VA
  • 11 ... 30 V DC or 11 ... 24 V AC

Power consumption

  • 230 V AC: 17 VA
  • 24 V AC : 9 W, I= 380 mA, IST = 8 A (30 ms)
  • 12 V DC : 11 W, I= 920 mA, IST = 4 A (250 ms)

Certificates and approvals

CE, ULc general purpose, C-tick; CSA/FM Class 1, div 2

Custody transfer approval (MAG 5000/6000 CT)

  • PTB OIML R49 (cold water pattern approval); MI-001
  • PTB and DANAK OIML R75 (hot water pattern approval) (MAG 6000 CT)
  • PTB and DANAK OIML R117 (cold water/milk, beer etc. pattern approval) (MAG 6000 CT)

Communication

 

Standard

 
  • MAG 5000

Without serial communication or HART as option

  • MAG 6000

Prepared for client mounted add-on modules

Optional (On MAG 6000 only)

HART, MODBUS RTU/RS485, FOUNDATION Fieldbus H1, DeviceNet, PROFIBUS PA, PROFIBUS DP as add-on modules

  • MAG 5000/6000 CT

no communication moduls approved


Safety barrier (e/ia)
 

Application

For use with MAG 5000/6000 19” and MAG 1100 Ex ATEX/MAG 3100 Ex ATEX

 

Ex approval

MAG 1100 Ex [EEx e ia] IIB ATEX

MAG 3100 Ex [EEx e ia] IIC ATEX

Cable parameter

  • Electrode

Group

Capacity in μF

Inductance in mH

IIC

≤ 4.1

≤ 80

IIB

≤ 45

≤ 87

IIA

≤ 45

≤ 87

 


Overview: